Modeling of ozone formation by a contact charger roller

Hiroyuki Kawamoto

研究成果: Article査読

11 被引用数 (Scopus)

抄録

Ozone formation by a contact charger roller was modeled on the basis of a one-dimensional static plasma reaction. The results of the investigation showed that though the calculated rate of ozone emission was about 1.7 times smaller than the experimental result, effects of applied ac voltage and its frequency qualitatively agreed with experiments. The following conclusions were deduced from the investigation: (1) the rate of ozone formation is roughly estimated using the present model; (2) the rate of ozone formation is large under high applied voltage and high-frequency operation, but the effect of the roller resistance is minor; and (3) it was proposed that a normalized cumulative charge density be minimized to suppress ozone formation. The present method may be utilized for the design of a contact charging subsystem and its operating conditions to reduce ozone emission.

本文言語English
ページ(範囲)267-271
ページ数5
ジャーナルJournal of Imaging Science and Technology
39
3
出版ステータスPublished - 1995 5
外部発表はい

ASJC Scopus subject areas

  • コンピュータ ビジョンおよびパターン認識
  • 電子材料、光学材料、および磁性材料

フィンガープリント

「Modeling of ozone formation by a contact charger roller」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。