Multi simulation model for Stirling and Vuilleumier cycle machines

Hiroshi Sekiya, Iwao Yamasita

研究成果: Article

抄録

The multi simulation model based on a so-called isothermal analysis has been newly developed for the primary performance prediction of both Stirling (ST) cycle machines and Vuilleumier (VM) cycle machines, which are realized as regenerative and external-combustion heat engines. The calculated results are compared with those by a so-called 3rd-order analysis, and the source of the difference between them is discussed. In addition, it is revealed by introducing an imaginary power piston into the present model that the VM cycle machine is internally divided into a ST cycle engine and a ST cycle refrigerator which jointly own the imaginary power piston. This means that the input power into the internal ST cycle refrigerator and the output power from the VM cycle machine which is obtained secondarily as a shaft horsepower are produced by the output power from the internal ST cycle engine.

元の言語English
ページ(範囲)3590-3597
ページ数8
ジャーナルNippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
57
発行部数542
出版物ステータスPublished - 1991 10
外部発表Yes

Fingerprint

Stirling cycle
Stirling engines
Refrigerators
Pistons
cycles
refrigerators
Heat engines
pistons
simulation
engines
horsepower
heat of combustion
heat engines
performance prediction
output

ASJC Scopus subject areas

  • Mechanical Engineering

これを引用

@article{f01d0aefea534fb0ad1250f254199db2,
title = "Multi simulation model for Stirling and Vuilleumier cycle machines",
abstract = "The multi simulation model based on a so-called isothermal analysis has been newly developed for the primary performance prediction of both Stirling (ST) cycle machines and Vuilleumier (VM) cycle machines, which are realized as regenerative and external-combustion heat engines. The calculated results are compared with those by a so-called 3rd-order analysis, and the source of the difference between them is discussed. In addition, it is revealed by introducing an imaginary power piston into the present model that the VM cycle machine is internally divided into a ST cycle engine and a ST cycle refrigerator which jointly own the imaginary power piston. This means that the input power into the internal ST cycle refrigerator and the output power from the VM cycle machine which is obtained secondarily as a shaft horsepower are produced by the output power from the internal ST cycle engine.",
author = "Hiroshi Sekiya and Iwao Yamasita",
year = "1991",
month = "10",
language = "English",
volume = "57",
pages = "3590--3597",
journal = "Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B",
issn = "0387-5016",
publisher = "Japan Society of Mechanical Engineers",
number = "542",

}

TY - JOUR

T1 - Multi simulation model for Stirling and Vuilleumier cycle machines

AU - Sekiya, Hiroshi

AU - Yamasita, Iwao

PY - 1991/10

Y1 - 1991/10

N2 - The multi simulation model based on a so-called isothermal analysis has been newly developed for the primary performance prediction of both Stirling (ST) cycle machines and Vuilleumier (VM) cycle machines, which are realized as regenerative and external-combustion heat engines. The calculated results are compared with those by a so-called 3rd-order analysis, and the source of the difference between them is discussed. In addition, it is revealed by introducing an imaginary power piston into the present model that the VM cycle machine is internally divided into a ST cycle engine and a ST cycle refrigerator which jointly own the imaginary power piston. This means that the input power into the internal ST cycle refrigerator and the output power from the VM cycle machine which is obtained secondarily as a shaft horsepower are produced by the output power from the internal ST cycle engine.

AB - The multi simulation model based on a so-called isothermal analysis has been newly developed for the primary performance prediction of both Stirling (ST) cycle machines and Vuilleumier (VM) cycle machines, which are realized as regenerative and external-combustion heat engines. The calculated results are compared with those by a so-called 3rd-order analysis, and the source of the difference between them is discussed. In addition, it is revealed by introducing an imaginary power piston into the present model that the VM cycle machine is internally divided into a ST cycle engine and a ST cycle refrigerator which jointly own the imaginary power piston. This means that the input power into the internal ST cycle refrigerator and the output power from the VM cycle machine which is obtained secondarily as a shaft horsepower are produced by the output power from the internal ST cycle engine.

UR - http://www.scopus.com/inward/record.url?scp=0026244410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026244410&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0026244410

VL - 57

SP - 3590

EP - 3597

JO - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B

JF - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B

SN - 0387-5016

IS - 542

ER -