OLTC and multiple SVRs in distribution system by using database

研究成果: Conference contribution

1 引用 (Scopus)

抄録

This paper presents a new method for determining the load drop compensator (LDC) parameters of On-load tap changer (OLTC) and step voltage regulators (SVRs) in the distribution system. Introduction of photovoltaic generation systems (PVs) into a distribution system makes determining the appropriate LDC parameters difficult, which may cause voltage deviation because reverse power flow from PVs affects voltage. Especially in the distribution system in which multiple SVRs are installed, determining the appropriate combination of LDC parameters becomes difficult. In the proposed method, the parameters are reset every hour by choosing one LDC parameter from a database including feasible parameters in the past. To create the database, the proposed method hourly enumerates the feasible parameters utilizing data acquired by SCADA. To evaluate the performance of the proposed method, the amount of voltage deviation of the proposed method will be compared with that of a centralized control method.

元の言語English
ホスト出版物のタイトルIYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy
出版者Institute of Electrical and Electronics Engineers Inc.
ISBN(印刷物)9781467371728
DOI
出版物ステータスPublished - 2015 8 5
イベント5th International Youth Conference on Energy, IYCE 2015 - Pisa, Italy
継続期間: 2015 5 272015 5 30

Other

Other5th International Youth Conference on Energy, IYCE 2015
Italy
Pisa
期間15/5/2715/5/30

Fingerprint

Voltage regulators
Electric potential

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Renewable Energy, Sustainability and the Environment
  • Electrical and Electronic Engineering

これを引用

Kawano, S., Yoshizawa, S., Fujimoto, Y., & Hayashi, Y. (2015). OLTC and multiple SVRs in distribution system by using database. : IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy [7180777] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/IYCE.2015.7180777

OLTC and multiple SVRs in distribution system by using database. / Kawano, Shunsuke; Yoshizawa, Shinya; Fujimoto, Yu; Hayashi, Yasuhiro.

IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy. Institute of Electrical and Electronics Engineers Inc., 2015. 7180777.

研究成果: Conference contribution

Kawano, S, Yoshizawa, S, Fujimoto, Y & Hayashi, Y 2015, OLTC and multiple SVRs in distribution system by using database. : IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy., 7180777, Institute of Electrical and Electronics Engineers Inc., 5th International Youth Conference on Energy, IYCE 2015, Pisa, Italy, 15/5/27. https://doi.org/10.1109/IYCE.2015.7180777
Kawano S, Yoshizawa S, Fujimoto Y, Hayashi Y. OLTC and multiple SVRs in distribution system by using database. : IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy. Institute of Electrical and Electronics Engineers Inc. 2015. 7180777 https://doi.org/10.1109/IYCE.2015.7180777
Kawano, Shunsuke ; Yoshizawa, Shinya ; Fujimoto, Yu ; Hayashi, Yasuhiro. / OLTC and multiple SVRs in distribution system by using database. IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy. Institute of Electrical and Electronics Engineers Inc., 2015.
@inproceedings{95b92eb010114c1fbd88db47f4482f2c,
title = "OLTC and multiple SVRs in distribution system by using database",
abstract = "This paper presents a new method for determining the load drop compensator (LDC) parameters of On-load tap changer (OLTC) and step voltage regulators (SVRs) in the distribution system. Introduction of photovoltaic generation systems (PVs) into a distribution system makes determining the appropriate LDC parameters difficult, which may cause voltage deviation because reverse power flow from PVs affects voltage. Especially in the distribution system in which multiple SVRs are installed, determining the appropriate combination of LDC parameters becomes difficult. In the proposed method, the parameters are reset every hour by choosing one LDC parameter from a database including feasible parameters in the past. To create the database, the proposed method hourly enumerates the feasible parameters utilizing data acquired by SCADA. To evaluate the performance of the proposed method, the amount of voltage deviation of the proposed method will be compared with that of a centralized control method.",
keywords = "decentralized voltage control, photovoltaic system, power distribution system, Smart Grids",
author = "Shunsuke Kawano and Shinya Yoshizawa and Yu Fujimoto and Yasuhiro Hayashi",
year = "2015",
month = "8",
day = "5",
doi = "10.1109/IYCE.2015.7180777",
language = "English",
isbn = "9781467371728",
booktitle = "IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - OLTC and multiple SVRs in distribution system by using database

AU - Kawano, Shunsuke

AU - Yoshizawa, Shinya

AU - Fujimoto, Yu

AU - Hayashi, Yasuhiro

PY - 2015/8/5

Y1 - 2015/8/5

N2 - This paper presents a new method for determining the load drop compensator (LDC) parameters of On-load tap changer (OLTC) and step voltage regulators (SVRs) in the distribution system. Introduction of photovoltaic generation systems (PVs) into a distribution system makes determining the appropriate LDC parameters difficult, which may cause voltage deviation because reverse power flow from PVs affects voltage. Especially in the distribution system in which multiple SVRs are installed, determining the appropriate combination of LDC parameters becomes difficult. In the proposed method, the parameters are reset every hour by choosing one LDC parameter from a database including feasible parameters in the past. To create the database, the proposed method hourly enumerates the feasible parameters utilizing data acquired by SCADA. To evaluate the performance of the proposed method, the amount of voltage deviation of the proposed method will be compared with that of a centralized control method.

AB - This paper presents a new method for determining the load drop compensator (LDC) parameters of On-load tap changer (OLTC) and step voltage regulators (SVRs) in the distribution system. Introduction of photovoltaic generation systems (PVs) into a distribution system makes determining the appropriate LDC parameters difficult, which may cause voltage deviation because reverse power flow from PVs affects voltage. Especially in the distribution system in which multiple SVRs are installed, determining the appropriate combination of LDC parameters becomes difficult. In the proposed method, the parameters are reset every hour by choosing one LDC parameter from a database including feasible parameters in the past. To create the database, the proposed method hourly enumerates the feasible parameters utilizing data acquired by SCADA. To evaluate the performance of the proposed method, the amount of voltage deviation of the proposed method will be compared with that of a centralized control method.

KW - decentralized voltage control

KW - photovoltaic system

KW - power distribution system

KW - Smart Grids

UR - http://www.scopus.com/inward/record.url?scp=84946213804&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84946213804&partnerID=8YFLogxK

U2 - 10.1109/IYCE.2015.7180777

DO - 10.1109/IYCE.2015.7180777

M3 - Conference contribution

AN - SCOPUS:84946213804

SN - 9781467371728

BT - IYCE 2015 - Proceedings: 2015 5th International Youth Conference on Energy

PB - Institute of Electrical and Electronics Engineers Inc.

ER -