Ozone generation in plasma actuator

Hiroyuki Kawamoto*, Toshimitsu Kobayashi

*この研究の対応する著者

    研究成果査読

    4 被引用数 (Scopus)

    抄録

    The generation of ozone in the plasma actuator that consists of simple parallel line electrodes separated by a thin dielectric layer was evaluated at the frequency less than 1000 Hz. It was measured that the ozone generation was increased under the conditions of high applied voltage and high frequency but irrelevant to the gap between the electrodes. The measured ozone concentration under the conditions of 6 kV -1000 Hz applied voltage and 1.5 liter/min flow rate was approximately 100 ppm, which is much higher than the human safety standard value of 0.1 ppm.

    本文言語English
    ページ(範囲)2345-2347
    ページ数3
    ジャーナルNihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
    75
    759
    出版ステータスPublished - 2009 11

    ASJC Scopus subject areas

    • 機械工学
    • 凝縮系物理学

    フィンガープリント

    「Ozone generation in plasma actuator」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

    引用スタイル