    This paper addresses a diagnostic palpation system based on the measurement of nonlinear elasticity. An indentation probe is used to press against breast tissue. Then, the measured reaction force is used to estimate the parameters of nonlinear elasticity, which enables the identification of tissue type, such as fat, muscle, mammary gland or tumor. Here, we present the basic concept of our study and preliminary experimental and simulation results from pilot studies. More specifically, we measured the nonlinear response of reaction force using the breast of a goat. In addition, we also simulated the reaction force using nonlinear biomechanical simulation with several tissue types. Large differences in reaction force occur only in the nonlinear range in both experimental and simulation situations. Our results confirmed the feasibility of our concept.

    元の言語English
    ホスト出版物のタイトルProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
    ページ7393-7396
    ページ数4
    DOI
    出版物ステータスPublished - 2011
    イベント33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011 - Boston, MA
    継続期間: 2011 8 302011 9 3

    Other

    Other33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
    Boston, MA
    期間11/8/3011/9/3

    Fingerprint

    Palpation
    Breast
    Elasticity
    Tissue
    Human Mammary Glands
    Oils and fats
    Indentation
    Goats
    Muscle
    Tumors
    Fats
    Breast Neoplasms
    Muscles

    ASJC Scopus subject areas

    • Computer Vision and Pattern Recognition
    • Signal Processing
    • Biomedical Engineering
    • Health Informatics

    これを引用

    Kobayashi, Y., Tsukune, M., Hoshi, T., Miyashita, T., Shiraishi, Y., Yambe, T., & Fujie, M. G. (2011). Palpation nonlinear reaction force analysis for characterization of breast tissues. : Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS (pp. 7393-7396). [6091721] https://doi.org/10.1109/IEMBS.2011.6091721

    Palpation nonlinear reaction force analysis for characterization of breast tissues. / Kobayashi, Yo; Tsukune, Mariko; Hoshi, Takeharu; Miyashita, Tomoyuki; Shiraishi, Yasuyuki; Yambe, Tomoyuki; Fujie, Masakatsu G.

    Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2011. p. 7393-7396 6091721.

    研究成果: Conference contribution

    Kobayashi, Y, Tsukune, M, Hoshi, T, Miyashita, T, Shiraishi, Y, Yambe, T & Fujie, MG 2011, Palpation nonlinear reaction force analysis for characterization of breast tissues. : Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS., 6091721, pp. 7393-7396, 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011, Boston, MA, 11/8/30. https://doi.org/10.1109/IEMBS.2011.6091721
    Kobayashi Y, Tsukune M, Hoshi T, Miyashita T, Shiraishi Y, Yambe T その他. Palpation nonlinear reaction force analysis for characterization of breast tissues. : Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2011. p. 7393-7396. 6091721 https://doi.org/10.1109/IEMBS.2011.6091721
    Kobayashi, Yo ; Tsukune, Mariko ; Hoshi, Takeharu ; Miyashita, Tomoyuki ; Shiraishi, Yasuyuki ; Yambe, Tomoyuki ; Fujie, Masakatsu G. / Palpation nonlinear reaction force analysis for characterization of breast tissues. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2011. pp. 7393-7396
    @inproceedings{090827accad5410ea0b8b1537ef9407d,
    title = "Palpation nonlinear reaction force analysis for characterization of breast tissues",
    abstract = "This paper addresses a diagnostic palpation system based on the measurement of nonlinear elasticity. An indentation probe is used to press against breast tissue. Then, the measured reaction force is used to estimate the parameters of nonlinear elasticity, which enables the identification of tissue type, such as fat, muscle, mammary gland or tumor. Here, we present the basic concept of our study and preliminary experimental and simulation results from pilot studies. More specifically, we measured the nonlinear response of reaction force using the breast of a goat. In addition, we also simulated the reaction force using nonlinear biomechanical simulation with several tissue types. Large differences in reaction force occur only in the nonlinear range in both experimental and simulation situations. Our results confirmed the feasibility of our concept.",
    author = "Yo Kobayashi and Mariko Tsukune and Takeharu Hoshi and Tomoyuki Miyashita and Yasuyuki Shiraishi and Tomoyuki Yambe and Fujie, {Masakatsu G.}",
    year = "2011",
    doi = "10.1109/IEMBS.2011.6091721",
    language = "English",
    isbn = "9781424441211",
    pages = "7393--7396",
    booktitle = "Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS",

    }

    TY - GEN

    T1 - Palpation nonlinear reaction force analysis for characterization of breast tissues

    AU - Kobayashi, Yo

    AU - Tsukune, Mariko

    AU - Hoshi, Takeharu

    AU - Miyashita, Tomoyuki

    AU - Shiraishi, Yasuyuki

    AU - Yambe, Tomoyuki

    AU - Fujie, Masakatsu G.

    PY - 2011

    Y1 - 2011

    N2 - This paper addresses a diagnostic palpation system based on the measurement of nonlinear elasticity. An indentation probe is used to press against breast tissue. Then, the measured reaction force is used to estimate the parameters of nonlinear elasticity, which enables the identification of tissue type, such as fat, muscle, mammary gland or tumor. Here, we present the basic concept of our study and preliminary experimental and simulation results from pilot studies. More specifically, we measured the nonlinear response of reaction force using the breast of a goat. In addition, we also simulated the reaction force using nonlinear biomechanical simulation with several tissue types. Large differences in reaction force occur only in the nonlinear range in both experimental and simulation situations. Our results confirmed the feasibility of our concept.

    AB - This paper addresses a diagnostic palpation system based on the measurement of nonlinear elasticity. An indentation probe is used to press against breast tissue. Then, the measured reaction force is used to estimate the parameters of nonlinear elasticity, which enables the identification of tissue type, such as fat, muscle, mammary gland or tumor. Here, we present the basic concept of our study and preliminary experimental and simulation results from pilot studies. More specifically, we measured the nonlinear response of reaction force using the breast of a goat. In addition, we also simulated the reaction force using nonlinear biomechanical simulation with several tissue types. Large differences in reaction force occur only in the nonlinear range in both experimental and simulation situations. Our results confirmed the feasibility of our concept.

    UR - http://www.scopus.com/inward/record.url?scp=84055214176&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84055214176&partnerID=8YFLogxK

    U2 - 10.1109/IEMBS.2011.6091721

    DO - 10.1109/IEMBS.2011.6091721

    M3 - Conference contribution

    C2 - 22256047

    SN - 9781424441211

    SP - 7393

    EP - 7396

    BT - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS

    ER -