抄録
SUMMARY The coupling coefficient between the coils of a noncontact power supply system is reduced by coil misalignment. This reduces the output voltage and the active power in the coils. To cope with these problems, an instantaneous current control method is applied to a single-phase contactless power transformer system in order to apply the equivalent impedance of the PWM rectifier at the load side of the transformer. We propose a control method to supply power constantly to the load even when there is a misalignment in the receiving coils. The limit of the transferred power associated with the proposed control method is investigated. The proposed system, including the control method, is verified by experimental tests over a power range of several tens of watts.
本文言語 | English |
---|---|
ページ(範囲) | 55-64 |
ページ数 | 10 |
ジャーナル | Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi) |
巻 | 193 |
号 | 1 |
DOI | |
出版ステータス | Published - 2015 1月 1 |
外部発表 | はい |
ASJC Scopus subject areas
- エネルギー工学および電力技術
- 電子工学および電気工学