Preliminary Pressure Measurement in the Range of 10-9 Pa Using a Picosecond Pulsed Laser

Kiyohide Kokubun, Sigeyuki Sekine, Shingo Ichimura, Hazime Shimizu

研究成果: Article

3 引用 (Scopus)

抄録

Results of the preliminary pressure measurement using a picosecond pulsed YAG laser are presented. By this method, pressures in the range of 10-9 Pa were measured for H2 gas. Advantages of this method and the problem of noise are discussed compared with the method using an excimer laser.

元の言語English
ページ(範囲)L1368-L1369
ジャーナルJapanese Journal of Applied Physics
32
発行部数9
DOI
出版物ステータスPublished - 1993 1 1
外部発表Yes

Fingerprint

Excimer lasers
pressure measurement
Pressure measurement
Pulsed lasers
excimer lasers
YAG lasers
pulsed lasers
Gases
gases

ASJC Scopus subject areas

  • Engineering(all)
  • Physics and Astronomy(all)

これを引用

Preliminary Pressure Measurement in the Range of 10-9 Pa Using a Picosecond Pulsed Laser. / Kokubun, Kiyohide; Sekine, Sigeyuki; Ichimura, Shingo; Shimizu, Hazime.

:: Japanese Journal of Applied Physics, 巻 32, 番号 9, 01.01.1993, p. L1368-L1369.

研究成果: Article

Kokubun, Kiyohide ; Sekine, Sigeyuki ; Ichimura, Shingo ; Shimizu, Hazime. / Preliminary Pressure Measurement in the Range of 10-9 Pa Using a Picosecond Pulsed Laser. :: Japanese Journal of Applied Physics. 1993 ; 巻 32, 番号 9. pp. L1368-L1369.
@article{19192d7fe48d4c17b87fca61dc8da1ad,
title = "Preliminary Pressure Measurement in the Range of 10-9 Pa Using a Picosecond Pulsed Laser",
abstract = "Results of the preliminary pressure measurement using a picosecond pulsed YAG laser are presented. By this method, pressures in the range of 10-9 Pa were measured for H2 gas. Advantages of this method and the problem of noise are discussed compared with the method using an excimer laser.",
author = "Kiyohide Kokubun and Sigeyuki Sekine and Shingo Ichimura and Hazime Shimizu",
year = "1993",
month = "1",
day = "1",
doi = "10.1143/JJAP.32.L1368",
language = "English",
volume = "32",
pages = "L1368--L1369",
journal = "Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes",
issn = "0021-4922",
publisher = "Japan Society of Applied Physics",
number = "9",

}

TY - JOUR

T1 - Preliminary Pressure Measurement in the Range of 10-9 Pa Using a Picosecond Pulsed Laser

AU - Kokubun, Kiyohide

AU - Sekine, Sigeyuki

AU - Ichimura, Shingo

AU - Shimizu, Hazime

PY - 1993/1/1

Y1 - 1993/1/1

N2 - Results of the preliminary pressure measurement using a picosecond pulsed YAG laser are presented. By this method, pressures in the range of 10-9 Pa were measured for H2 gas. Advantages of this method and the problem of noise are discussed compared with the method using an excimer laser.

AB - Results of the preliminary pressure measurement using a picosecond pulsed YAG laser are presented. By this method, pressures in the range of 10-9 Pa were measured for H2 gas. Advantages of this method and the problem of noise are discussed compared with the method using an excimer laser.

UR - http://www.scopus.com/inward/record.url?scp=0027660396&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027660396&partnerID=8YFLogxK

U2 - 10.1143/JJAP.32.L1368

DO - 10.1143/JJAP.32.L1368

M3 - Article

AN - SCOPUS:0027660396

VL - 32

SP - L1368-L1369

JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

SN - 0021-4922

IS - 9

ER -