TY - JOUR
T1 - Production and evaluation of stereoscopic video presentation in surgical training
AU - Ilgner, Justus
AU - Kawai, Takashi
AU - Westhofen, Martin
AU - Shibata, Takashi
PY - 2004/12/1
Y1 - 2004/12/1
N2 - Stereoscopic video teaching can facilitate understanding for current minimally-invasive operative techniques. This project was created to set up a digital stereoscopic teaching environment for training of ENT residents and medical students. We recorded three ENT operative procedures (tympanoplasty, paranasal sinus operation and laser chordectomy) at the University Hospital Aachen. The material was edited stereoscopically at the Waseda University and converted into a streaming 3-D video format, which does not depend on PAL or NTSC signal standards. Video clips were evaluated by 5 ENT specialists and 11 residents in single sessions on an LCD monitor (8) and a CRT monitor (8). Emphasis was laid on depth perception, visual fatigue and time to achieve stereoscopic impression. Qualitative results were recorded on a visual analogue scale, ranging from 1 (excellent) to 5 (bad). The overall impression was rated 2,06 to 3,13 in the LCD group and 2,0 to 2,62 in the CRT group. The depth impression was rated 1,63 to 2,88 (LCD) and 1,63 to 2,25 (CRT). Stereoscopic video teaching was regarded as useful in ENT training by all participants. Further points for evaluation will be the quantification of depth information as well as the information gain in teaching junior colleagues.
AB - Stereoscopic video teaching can facilitate understanding for current minimally-invasive operative techniques. This project was created to set up a digital stereoscopic teaching environment for training of ENT residents and medical students. We recorded three ENT operative procedures (tympanoplasty, paranasal sinus operation and laser chordectomy) at the University Hospital Aachen. The material was edited stereoscopically at the Waseda University and converted into a streaming 3-D video format, which does not depend on PAL or NTSC signal standards. Video clips were evaluated by 5 ENT specialists and 11 residents in single sessions on an LCD monitor (8) and a CRT monitor (8). Emphasis was laid on depth perception, visual fatigue and time to achieve stereoscopic impression. Qualitative results were recorded on a visual analogue scale, ranging from 1 (excellent) to 5 (bad). The overall impression was rated 2,06 to 3,13 in the LCD group and 2,0 to 2,62 in the CRT group. The depth impression was rated 1,63 to 2,88 (LCD) and 1,63 to 2,25 (CRT). Stereoscopic video teaching was regarded as useful in ENT training by all participants. Further points for evaluation will be the quantification of depth information as well as the information gain in teaching junior colleagues.
KW - Chronic sinusitis
KW - Larynx
KW - Medical education
KW - Microsurgery
KW - Minimally-invasive
KW - Otorhinolaryngology
KW - Stereoscopy
KW - Tympanoplasty
UR - http://www.scopus.com/inward/record.url?scp=8844276653&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=8844276653&partnerID=8YFLogxK
U2 - 10.1117/12.524274
DO - 10.1117/12.524274
M3 - Conference article
AN - SCOPUS:8844276653
SN - 0277-786X
VL - 5291
SP - 293
EP - 302
JO - Proceedings of SPIE - The International Society for Optical Engineering
JF - Proceedings of SPIE - The International Society for Optical Engineering
T2 - Stereoscopic Displays and Virtual Reality Systems XI
Y2 - 19 January 2004 through 21 January 2004
ER -