TY - JOUR
T1 - Prompt gamma-ray analysis (PGA) of meteorite samples, with emphasis on the determination of Si
AU - Latif, Sk A.
AU - Oura, Y.
AU - Ebihara, M.
AU - Kallemeyn, G. W.
AU - Nakahara, H.
AU - Yonezawa, C.
AU - Matsue, T.
AU - Sawahata, H.
PY - 1999
Y1 - 1999
N2 - Neutron-induced prompt gamma-ray analysis (PGA) was applied to seven meteorite samples (Allende, Zagami, Acfer 209, ALH77005, ALH84001, EET79001 and Neagari). Samples were irradiated in both the thermal neutron and the cold neutron guided beams of JRR-3M at JAERI. Multiple samples of an Allende standard powder were analyzed for Si using two different methods: (1) the comparison method, using a Si standard, and (2) the mono-standard method, using Fe as an internal reference element. The Si concentrations determined by these two methods are in good agreement with literature values. The analytical sensitivity for Si using the cold neutron guided beam is ~14.3x higher than that for the thermal neutron guided beam. Other elements determined (B, Ca, Ti and S) also showed higher sensitivities using the cold neutron beam. The other meteorites studied showed some anomalous B and S values likely due to the effects of terrestrial weathering/contamination.
AB - Neutron-induced prompt gamma-ray analysis (PGA) was applied to seven meteorite samples (Allende, Zagami, Acfer 209, ALH77005, ALH84001, EET79001 and Neagari). Samples were irradiated in both the thermal neutron and the cold neutron guided beams of JRR-3M at JAERI. Multiple samples of an Allende standard powder were analyzed for Si using two different methods: (1) the comparison method, using a Si standard, and (2) the mono-standard method, using Fe as an internal reference element. The Si concentrations determined by these two methods are in good agreement with literature values. The analytical sensitivity for Si using the cold neutron guided beam is ~14.3x higher than that for the thermal neutron guided beam. Other elements determined (B, Ca, Ti and S) also showed higher sensitivities using the cold neutron beam. The other meteorites studied showed some anomalous B and S values likely due to the effects of terrestrial weathering/contamination.
UR - http://www.scopus.com/inward/record.url?scp=0032954565&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032954565&partnerID=8YFLogxK
U2 - 10.1007/BF02349072
DO - 10.1007/BF02349072
M3 - Article
AN - SCOPUS:0032954565
VL - 239
SP - 577
EP - 580
JO - Journal of Radioanalytical and Nuclear Chemistry
JF - Journal of Radioanalytical and Nuclear Chemistry
SN - 0022-4081
IS - 3
ER -