Prompt response methods for a radiation detector

研究成果: Conference contribution

抄録

The ionizing radiation survey meter is an indispensable radiation detector in case of the radiation accident or the nuclear accident, and it is used as a typical equipment in the daily radiation control of radiation facilities. The survey meter measures dose rate (mSv/h) or count rate (min-1, sec-1). In general, about 30 sec per each place is necessary for the measurement, and the time of about 60 sec per each place is necessary for a more accurate measurement. The method, which predicts the final value at the initial stage without waiting for the final response has been proposed for the rapid measurement.

元の言語English
ホスト出版物のタイトルSICE 2005 Annual Conference in Okayama - Proceedings
ページ2155-2158
ページ数4
出版物ステータスPublished - 2005
外部発表Yes
イベントSICE Annual Conference 2005 - Okayama
継続期間: 2005 8 82005 8 10

Other

OtherSICE Annual Conference 2005
Okayama
期間05/8/805/8/10

Fingerprint

Radiation detectors
Nuclear reactor accidents
Radiation
Ionizing radiation
Dosimetry
Accidents

ASJC Scopus subject areas

  • Engineering(all)

これを引用

Shirakawa, Y. (2005). Prompt response methods for a radiation detector. : SICE 2005 Annual Conference in Okayama - Proceedings (pp. 2155-2158)

Prompt response methods for a radiation detector. / Shirakawa, Yoshiyuki.

SICE 2005 Annual Conference in Okayama - Proceedings. 2005. p. 2155-2158.

研究成果: Conference contribution

Shirakawa, Y 2005, Prompt response methods for a radiation detector. : SICE 2005 Annual Conference in Okayama - Proceedings. pp. 2155-2158, SICE Annual Conference 2005, Okayama, 05/8/8.
Shirakawa Y. Prompt response methods for a radiation detector. : SICE 2005 Annual Conference in Okayama - Proceedings. 2005. p. 2155-2158
Shirakawa, Yoshiyuki. / Prompt response methods for a radiation detector. SICE 2005 Annual Conference in Okayama - Proceedings. 2005. pp. 2155-2158
@inproceedings{97ba63c3c90e4755be123c84766d32ef,
title = "Prompt response methods for a radiation detector",
abstract = "The ionizing radiation survey meter is an indispensable radiation detector in case of the radiation accident or the nuclear accident, and it is used as a typical equipment in the daily radiation control of radiation facilities. The survey meter measures dose rate (mSv/h) or count rate (min-1, sec-1). In general, about 30 sec per each place is necessary for the measurement, and the time of about 60 sec per each place is necessary for a more accurate measurement. The method, which predicts the final value at the initial stage without waiting for the final response has been proposed for the rapid measurement.",
keywords = "Detector, Ionizing radiation, Prediction, Prompt response, Survey meter",
author = "Yoshiyuki Shirakawa",
year = "2005",
language = "English",
pages = "2155--2158",
booktitle = "SICE 2005 Annual Conference in Okayama - Proceedings",

}

TY - GEN

T1 - Prompt response methods for a radiation detector

AU - Shirakawa, Yoshiyuki

PY - 2005

Y1 - 2005

N2 - The ionizing radiation survey meter is an indispensable radiation detector in case of the radiation accident or the nuclear accident, and it is used as a typical equipment in the daily radiation control of radiation facilities. The survey meter measures dose rate (mSv/h) or count rate (min-1, sec-1). In general, about 30 sec per each place is necessary for the measurement, and the time of about 60 sec per each place is necessary for a more accurate measurement. The method, which predicts the final value at the initial stage without waiting for the final response has been proposed for the rapid measurement.

AB - The ionizing radiation survey meter is an indispensable radiation detector in case of the radiation accident or the nuclear accident, and it is used as a typical equipment in the daily radiation control of radiation facilities. The survey meter measures dose rate (mSv/h) or count rate (min-1, sec-1). In general, about 30 sec per each place is necessary for the measurement, and the time of about 60 sec per each place is necessary for a more accurate measurement. The method, which predicts the final value at the initial stage without waiting for the final response has been proposed for the rapid measurement.

KW - Detector

KW - Ionizing radiation

KW - Prediction

KW - Prompt response

KW - Survey meter

UR - http://www.scopus.com/inward/record.url?scp=33645285285&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33645285285&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:33645285285

SP - 2155

EP - 2158

BT - SICE 2005 Annual Conference in Okayama - Proceedings

ER -