Quantitative surface chemical analysis of AuCu alloys with aes

K. Yoshihara, R. Shimizu, T. Homma, H. Tokutaka, K. Goto, M. Uemura, D. Fujita, A. Kurokawa, Shingo Ichimura, C. Oshima, M. Kurahashi, M. Kudo, Y. Hashiguchi, Y. Fukuda, T. Suzuki, T. Ohmura, F. Soeda, K. Tanaka, A. Tanaka, T. SekineY. Shiokawa, T. Hayashi

研究成果: Article

24 引用 (Scopus)

抄録

The Japanese VAMAS‐SCA working group is composed of 19 institutes. Three kinds of Au‐Cu alloys (Au25 at%‐Cu75 at%, Au50 at%‐Cu50 at%, Au75 at%‐Cu25 at%) were prepared, and these specimens were distributed to the members of Japanese VAMAS‐SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter‐laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.

元の言語English
ページ(範囲)125-130
ページ数6
ジャーナルSurface and Interface Analysis
12
発行部数2
DOI
出版物ステータスPublished - 1988 1 1
外部発表Yes

Fingerprint

chemical analysis
Spectrometers
spectrometers
Chemical analysis
sensitivity
energy

ASJC Scopus subject areas

  • Chemistry(all)
  • Condensed Matter Physics
  • Surfaces and Interfaces
  • Surfaces, Coatings and Films
  • Materials Chemistry

これを引用

Yoshihara, K., Shimizu, R., Homma, T., Tokutaka, H., Goto, K., Uemura, M., ... Hayashi, T. (1988). Quantitative surface chemical analysis of AuCu alloys with aes. Surface and Interface Analysis, 12(2), 125-130. https://doi.org/10.1002/sia.740120212

Quantitative surface chemical analysis of AuCu alloys with aes. / Yoshihara, K.; Shimizu, R.; Homma, T.; Tokutaka, H.; Goto, K.; Uemura, M.; Fujita, D.; Kurokawa, A.; Ichimura, Shingo; Oshima, C.; Kurahashi, M.; Kudo, M.; Hashiguchi, Y.; Fukuda, Y.; Suzuki, T.; Ohmura, T.; Soeda, F.; Tanaka, K.; Tanaka, A.; Sekine, T.; Shiokawa, Y.; Hayashi, T.

:: Surface and Interface Analysis, 巻 12, 番号 2, 01.01.1988, p. 125-130.

研究成果: Article

Yoshihara, K, Shimizu, R, Homma, T, Tokutaka, H, Goto, K, Uemura, M, Fujita, D, Kurokawa, A, Ichimura, S, Oshima, C, Kurahashi, M, Kudo, M, Hashiguchi, Y, Fukuda, Y, Suzuki, T, Ohmura, T, Soeda, F, Tanaka, K, Tanaka, A, Sekine, T, Shiokawa, Y & Hayashi, T 1988, 'Quantitative surface chemical analysis of AuCu alloys with aes', Surface and Interface Analysis, 巻. 12, 番号 2, pp. 125-130. https://doi.org/10.1002/sia.740120212
Yoshihara K, Shimizu R, Homma T, Tokutaka H, Goto K, Uemura M その他. Quantitative surface chemical analysis of AuCu alloys with aes. Surface and Interface Analysis. 1988 1 1;12(2):125-130. https://doi.org/10.1002/sia.740120212
Yoshihara, K. ; Shimizu, R. ; Homma, T. ; Tokutaka, H. ; Goto, K. ; Uemura, M. ; Fujita, D. ; Kurokawa, A. ; Ichimura, Shingo ; Oshima, C. ; Kurahashi, M. ; Kudo, M. ; Hashiguchi, Y. ; Fukuda, Y. ; Suzuki, T. ; Ohmura, T. ; Soeda, F. ; Tanaka, K. ; Tanaka, A. ; Sekine, T. ; Shiokawa, Y. ; Hayashi, T. / Quantitative surface chemical analysis of AuCu alloys with aes. :: Surface and Interface Analysis. 1988 ; 巻 12, 番号 2. pp. 125-130.
@article{4028916ad5eb4d9d83f8ddf4cd834ea2,
title = "Quantitative surface chemical analysis of AuCu alloys with aes",
abstract = "The Japanese VAMAS‐SCA working group is composed of 19 institutes. Three kinds of Au‐Cu alloys (Au25 at{\%}‐Cu75 at{\%}, Au50 at{\%}‐Cu50 at{\%}, Au75 at{\%}‐Cu25 at{\%}) were prepared, and these specimens were distributed to the members of Japanese VAMAS‐SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter‐laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.",
author = "K. Yoshihara and R. Shimizu and T. Homma and H. Tokutaka and K. Goto and M. Uemura and D. Fujita and A. Kurokawa and Shingo Ichimura and C. Oshima and M. Kurahashi and M. Kudo and Y. Hashiguchi and Y. Fukuda and T. Suzuki and T. Ohmura and F. Soeda and K. Tanaka and A. Tanaka and T. Sekine and Y. Shiokawa and T. Hayashi",
year = "1988",
month = "1",
day = "1",
doi = "10.1002/sia.740120212",
language = "English",
volume = "12",
pages = "125--130",
journal = "Surface and Interface Analysis",
issn = "0142-2421",
publisher = "John Wiley and Sons Ltd",
number = "2",

}

TY - JOUR

T1 - Quantitative surface chemical analysis of AuCu alloys with aes

AU - Yoshihara, K.

AU - Shimizu, R.

AU - Homma, T.

AU - Tokutaka, H.

AU - Goto, K.

AU - Uemura, M.

AU - Fujita, D.

AU - Kurokawa, A.

AU - Ichimura, Shingo

AU - Oshima, C.

AU - Kurahashi, M.

AU - Kudo, M.

AU - Hashiguchi, Y.

AU - Fukuda, Y.

AU - Suzuki, T.

AU - Ohmura, T.

AU - Soeda, F.

AU - Tanaka, K.

AU - Tanaka, A.

AU - Sekine, T.

AU - Shiokawa, Y.

AU - Hayashi, T.

PY - 1988/1/1

Y1 - 1988/1/1

N2 - The Japanese VAMAS‐SCA working group is composed of 19 institutes. Three kinds of Au‐Cu alloys (Au25 at%‐Cu75 at%, Au50 at%‐Cu50 at%, Au75 at%‐Cu25 at%) were prepared, and these specimens were distributed to the members of Japanese VAMAS‐SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter‐laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.

AB - The Japanese VAMAS‐SCA working group is composed of 19 institutes. Three kinds of Au‐Cu alloys (Au25 at%‐Cu75 at%, Au50 at%‐Cu50 at%, Au75 at%‐Cu25 at%) were prepared, and these specimens were distributed to the members of Japanese VAMAS‐SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter‐laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.

UR - http://www.scopus.com/inward/record.url?scp=0024037766&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024037766&partnerID=8YFLogxK

U2 - 10.1002/sia.740120212

DO - 10.1002/sia.740120212

M3 - Article

AN - SCOPUS:0024037766

VL - 12

SP - 125

EP - 130

JO - Surface and Interface Analysis

JF - Surface and Interface Analysis

SN - 0142-2421

IS - 2

ER -