TY - JOUR
T1 - Research on the gait analysis of the spastic paralysis using the measurement orthosis
AU - Mine, Yasuhiro
AU - Kobayashi, Yoshiyuki
AU - Takashima, Takamichi
AU - Fujimoto, Hiroshi
PY - 2006/10
Y1 - 2006/10
N2 - We developed the SMO (Spastic Measurement orthosis) in order to measure the feature of spasticity by the paralysis of stroke. Because we focused on patients suffering from hemiplegies stroke in order to develop a design method of an AFO, which fit patients even more. Experiment method : Experiment system was consisted combining 3D Video Tracking system of 12CCD-camera and 8 force plates and SMO. Subjects of the experiment were conducted by healthy person and four stroke persons. Each subject who wore the SMO walked on the floor reaction force by usual walk. Experiment Result : Each subject's ankle joint moment was calculated and these experiments data were evaluated by comparison of the moment of SMO and foot angle at the Heel contact, paying attention to heel contact required for orthosis prescription. The possibility in order to determine of requirements for the design orthosis was suggested from these experiment results.
AB - We developed the SMO (Spastic Measurement orthosis) in order to measure the feature of spasticity by the paralysis of stroke. Because we focused on patients suffering from hemiplegies stroke in order to develop a design method of an AFO, which fit patients even more. Experiment method : Experiment system was consisted combining 3D Video Tracking system of 12CCD-camera and 8 force plates and SMO. Subjects of the experiment were conducted by healthy person and four stroke persons. Each subject who wore the SMO walked on the floor reaction force by usual walk. Experiment Result : Each subject's ankle joint moment was calculated and these experiments data were evaluated by comparison of the moment of SMO and foot angle at the Heel contact, paying attention to heel contact required for orthosis prescription. The possibility in order to determine of requirements for the design orthosis was suggested from these experiment results.
KW - Design
KW - Hemiplegies gait
KW - Human engineering
KW - Measurement
KW - Spasticity
UR - http://www.scopus.com/inward/record.url?scp=33846492924&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33846492924&partnerID=8YFLogxK
U2 - 10.1299/kikaic.72.3280
DO - 10.1299/kikaic.72.3280
M3 - Article
AN - SCOPUS:33846492924
VL - 72
SP - 3280
EP - 3285
JO - Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
JF - Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
SN - 0387-5024
IS - 10
ER -