Shintake monitor in ATF2: Performance evaluation

Yohei Yamaguchi, Takashi Yamanaka, Masahiro Oroku, Yoshio Kamiya, Sachio Komamiya, Taikan Suehara, Toshiyuki Okugi, Nobuhiro Terunuma, Toshiaki Tauchi, Sakae Araki, Junji Urakawa

研究成果: Paper

抄録

The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30% for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.

元の言語English
出版物ステータスPublished - 2010 12 1
外部発表Yes
イベント2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010 - Beijing, China
継続期間: 2010 3 262010 3 30

Other

Other2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010
China
Beijing
期間10/3/2610/3/30

Fingerprint

monitors
systematic errors
evaluation
diffraction patterns
interference
modulation
lasers

ASJC Scopus subject areas

  • Nuclear and High Energy Physics

これを引用

Yamaguchi, Y., Yamanaka, T., Oroku, M., Kamiya, Y., Komamiya, S., Suehara, T., ... Urakawa, J. (2010). Shintake monitor in ATF2: Performance evaluation. 論文発表場所 2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010, Beijing, China.

Shintake monitor in ATF2 : Performance evaluation. / Yamaguchi, Yohei; Yamanaka, Takashi; Oroku, Masahiro; Kamiya, Yoshio; Komamiya, Sachio; Suehara, Taikan; Okugi, Toshiyuki; Terunuma, Nobuhiro; Tauchi, Toshiaki; Araki, Sakae; Urakawa, Junji.

2010. 論文発表場所 2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010, Beijing, China.

研究成果: Paper

Yamaguchi, Y, Yamanaka, T, Oroku, M, Kamiya, Y, Komamiya, S, Suehara, T, Okugi, T, Terunuma, N, Tauchi, T, Araki, S & Urakawa, J 2010, 'Shintake monitor in ATF2: Performance evaluation', 論文発表場所 2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010, Beijing, China, 10/3/26 - 10/3/30.
Yamaguchi Y, Yamanaka T, Oroku M, Kamiya Y, Komamiya S, Suehara T その他. Shintake monitor in ATF2: Performance evaluation. 2010. 論文発表場所 2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010, Beijing, China.
Yamaguchi, Yohei ; Yamanaka, Takashi ; Oroku, Masahiro ; Kamiya, Yoshio ; Komamiya, Sachio ; Suehara, Taikan ; Okugi, Toshiyuki ; Terunuma, Nobuhiro ; Tauchi, Toshiaki ; Araki, Sakae ; Urakawa, Junji. / Shintake monitor in ATF2 : Performance evaluation. 論文発表場所 2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010, Beijing, China.
@conference{a61268414e1f4671a3f375c4e8e56a03,
title = "Shintake monitor in ATF2: Performance evaluation",
abstract = "The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30{\%} for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.",
author = "Yohei Yamaguchi and Takashi Yamanaka and Masahiro Oroku and Yoshio Kamiya and Sachio Komamiya and Taikan Suehara and Toshiyuki Okugi and Nobuhiro Terunuma and Toshiaki Tauchi and Sakae Araki and Junji Urakawa",
year = "2010",
month = "12",
day = "1",
language = "English",
note = "2010 Linear Collider Workshop, LCWS 2010 and International Linear Collider Meeting, ILC 2010 ; Conference date: 26-03-2010 Through 30-03-2010",

}

TY - CONF

T1 - Shintake monitor in ATF2

T2 - Performance evaluation

AU - Yamaguchi, Yohei

AU - Yamanaka, Takashi

AU - Oroku, Masahiro

AU - Kamiya, Yoshio

AU - Komamiya, Sachio

AU - Suehara, Taikan

AU - Okugi, Toshiyuki

AU - Terunuma, Nobuhiro

AU - Tauchi, Toshiaki

AU - Araki, Sakae

AU - Urakawa, Junji

PY - 2010/12/1

Y1 - 2010/12/1

N2 - The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30% for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.

AB - The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30% for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.

UR - http://www.scopus.com/inward/record.url?scp=84884604985&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84884604985&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:84884604985

ER -