Study on the total energy system of the gas turbine

OY YANG OY, T SHIMADA T, K TANISHITA K, GT SATO GT

研究成果: Chapter

7 引用 (Scopus)

抄録

In this paper, the basic thermodynamic characteristics of the plant which satisfies two requirements, such as electric power generation and central heating and cooling, are discussed. The high temperature of turbine exhaust causes a lower thermal efficiency than other conventional prime movers. Recovered wasted heat is converted to shaft power and available heat. The excess air ratio in the gas turbine cycle is so large that supplementary fuel can be fired in the waste heat boiler. Thus, by controlling the supplementary fuel and the bypass valve of the regenerator, this system showsfine flexibility in its operation. Also, the characteristic chart of this total energy system in part- load is presented for determining the opeating conditions.

元の言語English
ホスト出版物のタイトルBull JSME
ページ234-247
ページ数14
14
エディション69
出版物ステータスPublished - 1971 3

Fingerprint

Gas turbines
Electric power generation
Regenerators
Waste heat
Boilers
Turbines
Thermodynamics
Cooling
Heating
Air
Hot Temperature
Temperature

ASJC Scopus subject areas

  • Engineering(all)

これを引用

YANG OY, OY., SHIMADA T, T., TANISHITA K, K., & SATO GT, GT. (1971). Study on the total energy system of the gas turbine. : Bull JSME (69 版, 巻 14, pp. 234-247)

Study on the total energy system of the gas turbine. / YANG OY, OY; SHIMADA T, T; TANISHITA K, K; SATO GT, GT.

Bull JSME. 巻 14 69. 編 1971. p. 234-247.

研究成果: Chapter

YANG OY, OY, SHIMADA T, T, TANISHITA K, K & SATO GT, GT 1971, Study on the total energy system of the gas turbine. : Bull JSME. 69 Edn, 巻. 14, pp. 234-247.
YANG OY OY, SHIMADA T T, TANISHITA K K, SATO GT GT. Study on the total energy system of the gas turbine. : Bull JSME. 69 版 巻 14. 1971. p. 234-247
YANG OY, OY ; SHIMADA T, T ; TANISHITA K, K ; SATO GT, GT. / Study on the total energy system of the gas turbine. Bull JSME. 巻 14 69. 版 1971. pp. 234-247
@inbook{be7e9b58402947ea8adb0d5b0431881b,
title = "Study on the total energy system of the gas turbine",
abstract = "In this paper, the basic thermodynamic characteristics of the plant which satisfies two requirements, such as electric power generation and central heating and cooling, are discussed. The high temperature of turbine exhaust causes a lower thermal efficiency than other conventional prime movers. Recovered wasted heat is converted to shaft power and available heat. The excess air ratio in the gas turbine cycle is so large that supplementary fuel can be fired in the waste heat boiler. Thus, by controlling the supplementary fuel and the bypass valve of the regenerator, this system showsfine flexibility in its operation. Also, the characteristic chart of this total energy system in part- load is presented for determining the opeating conditions.",
author = "{YANG OY}, OY and {SHIMADA T}, T and {TANISHITA K}, K and {SATO GT}, GT",
year = "1971",
month = "3",
language = "English",
volume = "14",
pages = "234--247",
booktitle = "Bull JSME",
edition = "69",

}

TY - CHAP

T1 - Study on the total energy system of the gas turbine

AU - YANG OY, OY

AU - SHIMADA T, T

AU - TANISHITA K, K

AU - SATO GT, GT

PY - 1971/3

Y1 - 1971/3

N2 - In this paper, the basic thermodynamic characteristics of the plant which satisfies two requirements, such as electric power generation and central heating and cooling, are discussed. The high temperature of turbine exhaust causes a lower thermal efficiency than other conventional prime movers. Recovered wasted heat is converted to shaft power and available heat. The excess air ratio in the gas turbine cycle is so large that supplementary fuel can be fired in the waste heat boiler. Thus, by controlling the supplementary fuel and the bypass valve of the regenerator, this system showsfine flexibility in its operation. Also, the characteristic chart of this total energy system in part- load is presented for determining the opeating conditions.

AB - In this paper, the basic thermodynamic characteristics of the plant which satisfies two requirements, such as electric power generation and central heating and cooling, are discussed. The high temperature of turbine exhaust causes a lower thermal efficiency than other conventional prime movers. Recovered wasted heat is converted to shaft power and available heat. The excess air ratio in the gas turbine cycle is so large that supplementary fuel can be fired in the waste heat boiler. Thus, by controlling the supplementary fuel and the bypass valve of the regenerator, this system showsfine flexibility in its operation. Also, the characteristic chart of this total energy system in part- load is presented for determining the opeating conditions.

UR - http://www.scopus.com/inward/record.url?scp=0015037364&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0015037364&partnerID=8YFLogxK

M3 - Chapter

AN - SCOPUS:0015037364

VL - 14

SP - 234

EP - 247

BT - Bull JSME

ER -