Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect

Takuya Shimotsu, Kota Koike, Keiichiro Kondo

研究成果: Conference contribution

抄録

In this paper, a heat equivalent circuit model of 300 kW class transformer coil for contactless power transfer (CPT) system is proposed to estimate coils temperature rise. This model is featured by considering the differences of the heat generation of the AC resistance loss due to the high frequency flux. It is revealed by means of this model that 10 minute operation of a 300 kW CPT transformer is possible.

元の言語English
ホスト出版物のタイトル19th International Conference on Electrical Machines and Systems, ICEMS 2016
出版者Institute of Electrical and Electronics Engineers Inc.
ISBN(電子版)9784886860989
出版物ステータスPublished - 2017 1 30
外部発表Yes
イベント19th International Conference on Electrical Machines and Systems, ICEMS 2016 - Chiba, Japan
継続期間: 2016 11 132016 11 16

Other

Other19th International Conference on Electrical Machines and Systems, ICEMS 2016
Japan
Chiba
期間16/11/1316/11/16

Fingerprint

Skin effect
Power transformers
Heat generation
Equivalent circuits
Temperature
Fluxes
Inductive power transmission

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Mechanical Engineering

これを引用

Shimotsu, T., Koike, K., & Kondo, K. (2017). Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect. : 19th International Conference on Electrical Machines and Systems, ICEMS 2016 [7837180] Institute of Electrical and Electronics Engineers Inc..

Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect. / Shimotsu, Takuya; Koike, Kota; Kondo, Keiichiro.

19th International Conference on Electrical Machines and Systems, ICEMS 2016. Institute of Electrical and Electronics Engineers Inc., 2017. 7837180.

研究成果: Conference contribution

Shimotsu, T, Koike, K & Kondo, K 2017, Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect. : 19th International Conference on Electrical Machines and Systems, ICEMS 2016., 7837180, Institute of Electrical and Electronics Engineers Inc., 19th International Conference on Electrical Machines and Systems, ICEMS 2016, Chiba, Japan, 16/11/13.
Shimotsu T, Koike K, Kondo K. Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect. : 19th International Conference on Electrical Machines and Systems, ICEMS 2016. Institute of Electrical and Electronics Engineers Inc. 2017. 7837180
Shimotsu, Takuya ; Koike, Kota ; Kondo, Keiichiro. / Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect. 19th International Conference on Electrical Machines and Systems, ICEMS 2016. Institute of Electrical and Electronics Engineers Inc., 2017.
@inproceedings{598237d1430f4b9a84cd9e935f21240a,
title = "Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect",
abstract = "In this paper, a heat equivalent circuit model of 300 kW class transformer coil for contactless power transfer (CPT) system is proposed to estimate coils temperature rise. This model is featured by considering the differences of the heat generation of the AC resistance loss due to the high frequency flux. It is revealed by means of this model that 10 minute operation of a 300 kW CPT transformer is possible.",
keywords = "Contactless power transfer (CPT), heat equivalent circuit, high power, temperature rise",
author = "Takuya Shimotsu and Kota Koike and Keiichiro Kondo",
year = "2017",
month = "1",
day = "30",
language = "English",
booktitle = "19th International Conference on Electrical Machines and Systems, ICEMS 2016",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Temperature rise estimation of high power transformer of contactless power transfer system considering the influence of skin effect and proximity effect

AU - Shimotsu, Takuya

AU - Koike, Kota

AU - Kondo, Keiichiro

PY - 2017/1/30

Y1 - 2017/1/30

N2 - In this paper, a heat equivalent circuit model of 300 kW class transformer coil for contactless power transfer (CPT) system is proposed to estimate coils temperature rise. This model is featured by considering the differences of the heat generation of the AC resistance loss due to the high frequency flux. It is revealed by means of this model that 10 minute operation of a 300 kW CPT transformer is possible.

AB - In this paper, a heat equivalent circuit model of 300 kW class transformer coil for contactless power transfer (CPT) system is proposed to estimate coils temperature rise. This model is featured by considering the differences of the heat generation of the AC resistance loss due to the high frequency flux. It is revealed by means of this model that 10 minute operation of a 300 kW CPT transformer is possible.

KW - Contactless power transfer (CPT)

KW - heat equivalent circuit

KW - high power

KW - temperature rise

UR - http://www.scopus.com/inward/record.url?scp=85015104319&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85015104319&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:85015104319

BT - 19th International Conference on Electrical Machines and Systems, ICEMS 2016

PB - Institute of Electrical and Electronics Engineers Inc.

ER -