The lhcf detector at the cern large hadron collider

O. Adriani, L. Bonechi, M. Bongi, G. Castellini, R. D'Alessandro, D. A. Faus, K. Fukui, M. Grandi, M. Haguenauer, Y. Itow, K. Kasahara, D. Macina, T. Mase, K. Masuda, Y. Matsubara, H. Menjo, M. Mizuishi, Y. Muraki, P. Papini, A. L. PerrotS. Ricciarini, T. Sako, Y. Shimizu, K. Taki, T. Tamura, Shoji Torii, A. Tricomi, W. C. Turner, J. Velasco, A. Viciani, H. Watanabe, K. Yoshida

    研究成果: Article

    108 引用 (Scopus)

    抜粋

    LHCf is an experiment dedicated to the measurement of neutral particles emitted in the very forward region of LHC collisions. The physics goal is to provide data for calibrating the hadron interaction models that are used in the study of Extremely High-Energy Cosmic-Rays. This is possible since the laboratory equivalent collision energy of LHC is 1017 eV. Two LHCf detectors, consisting of imaging calorimeters made of tungsten plates, plastic scintillator and position sensitive sensors, are installed at zero degree collision angle ±140 m from an interaction point (IP). Although the lateral dimensions of these calorimeters are very compact, ranging from 20 mmx20 mm to 40 mmx40 mm, the energy resolution is expected to be better than 6% and the position resolution better than 0.2 mm for γ-rays with energy from 100 GeV to 7 TeV. This has been confirmed by test beam results at the CERN SPS. These calorimeters can measure particles emitted in the pseudo rapidity range n >8.4. Detectors, data acquisition and electronics are optimized to operate during the early phase of the LHC commissioning with luminosity below 10 30 cm-2s-1. LHCf is expected to obtain data to compare with the major hadron interaction models within a week or so of operation at luminosity ∼ 1029 cm-2s-1. After ∼10 days of operation at luminosity <∼-41029cm -2s-1, the light output of the plastic scintillators is expected to degrade by ∼10% due to radiation damage. This degradation will be monitored and corrected for using calibration pulses from a laser.

    元の言語English
    記事番号S08006
    ジャーナルJournal of Instrumentation
    3
    発行部数8
    DOI
    出版物ステータスPublished - 2008

    ASJC Scopus subject areas

    • Instrumentation
    • Mathematical Physics

    フィンガープリント The lhcf detector at the cern large hadron collider' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。

  • これを引用

    Adriani, O., Bonechi, L., Bongi, M., Castellini, G., D'Alessandro, R., Faus, D. A., Fukui, K., Grandi, M., Haguenauer, M., Itow, Y., Kasahara, K., Macina, D., Mase, T., Masuda, K., Matsubara, Y., Menjo, H., Mizuishi, M., Muraki, Y., Papini, P., ... Yoshida, K. (2008). The lhcf detector at the cern large hadron collider. Journal of Instrumentation, 3(8), [S08006]. https://doi.org/10.1088/1748-0221/3/08/S08006