THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY.

T. Nakatani, H. Takano, T. Taenaka, Mitsuo Umezu, T. Tanaka, C. Yutani, T. Matsuda, H. Iwata, H. Noda, T. Nakamura, S. Takatani, J. Seki, K. Hayashi, T. Akutsu, H. Manabe

研究成果: Conference contribution

7 引用 (Scopus)

抄録

Recently the left ventricular assist device (LVAD) has been applied to treatment of profound left ventricular failure (LVF) because of its ability to effectively replace cardiac pump function. For clinical use, the authors have developed a new LVAD system consisting of an air-driven, diaphragm-type pump and an automatic control drive unit. In the research reported in this paper, the authors have evaluated the effect of this LVAD system on profound LVF in chronic animal experiments and studied the recovery process of the failing heart from induced profound LVF using left ventriculography (LVG) as well as conventional hemodynamic parameters.

元の言語English
ホスト出版物のタイトルTransactions - American Society for Artificial Internal Organs
ページ533-539
ページ数7
30
出版物ステータスPublished - 1984
外部発表Yes

Fingerprint

Left ventricular assist devices
Heart-Assist Devices
Therapeutic Uses
Pumps
Hemodynamics
Diaphragms
Diaphragm
Animals
Air
Recovery
Research
Experiments

ASJC Scopus subject areas

  • Engineering(all)
  • Medicine(all)

これを引用

Nakatani, T., Takano, H., Taenaka, T., Umezu, M., Tanaka, T., Yutani, C., ... Manabe, H. (1984). THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY.Transactions - American Society for Artificial Internal Organs (巻 30, pp. 533-539)

THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY. / Nakatani, T.; Takano, H.; Taenaka, T.; Umezu, Mitsuo; Tanaka, T.; Yutani, C.; Matsuda, T.; Iwata, H.; Noda, H.; Nakamura, T.; Takatani, S.; Seki, J.; Hayashi, K.; Akutsu, T.; Manabe, H.

Transactions - American Society for Artificial Internal Organs. 巻 30 1984. p. 533-539.

研究成果: Conference contribution

Nakatani, T, Takano, H, Taenaka, T, Umezu, M, Tanaka, T, Yutani, C, Matsuda, T, Iwata, H, Noda, H, Nakamura, T, Takatani, S, Seki, J, Hayashi, K, Akutsu, T & Manabe, H 1984, THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY.Transactions - American Society for Artificial Internal Organs. 巻. 30, pp. 533-539.
Nakatani T, Takano H, Taenaka T, Umezu M, Tanaka T, Yutani C その他. THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY. : Transactions - American Society for Artificial Internal Organs. 巻 30. 1984. p. 533-539
Nakatani, T. ; Takano, H. ; Taenaka, T. ; Umezu, Mitsuo ; Tanaka, T. ; Yutani, C. ; Matsuda, T. ; Iwata, H. ; Noda, H. ; Nakamura, T. ; Takatani, S. ; Seki, J. ; Hayashi, K. ; Akutsu, T. ; Manabe, H. / THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY. Transactions - American Society for Artificial Internal Organs. 巻 30 1984. pp. 533-539
@inproceedings{a463562e3e544d868af1871904e373d1,
title = "THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY.",
abstract = "Recently the left ventricular assist device (LVAD) has been applied to treatment of profound left ventricular failure (LVF) because of its ability to effectively replace cardiac pump function. For clinical use, the authors have developed a new LVAD system consisting of an air-driven, diaphragm-type pump and an automatic control drive unit. In the research reported in this paper, the authors have evaluated the effect of this LVAD system on profound LVF in chronic animal experiments and studied the recovery process of the failing heart from induced profound LVF using left ventriculography (LVG) as well as conventional hemodynamic parameters.",
author = "T. Nakatani and H. Takano and T. Taenaka and Mitsuo Umezu and T. Tanaka and C. Yutani and T. Matsuda and H. Iwata and H. Noda and T. Nakamura and S. Takatani and J. Seki and K. Hayashi and T. Akutsu and H. Manabe",
year = "1984",
language = "English",
volume = "30",
pages = "533--539",
booktitle = "Transactions - American Society for Artificial Internal Organs",

}

TY - GEN

T1 - THERAPEUTIC EFFECT OF LEFT VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY.

AU - Nakatani, T.

AU - Takano, H.

AU - Taenaka, T.

AU - Umezu, Mitsuo

AU - Tanaka, T.

AU - Yutani, C.

AU - Matsuda, T.

AU - Iwata, H.

AU - Noda, H.

AU - Nakamura, T.

AU - Takatani, S.

AU - Seki, J.

AU - Hayashi, K.

AU - Akutsu, T.

AU - Manabe, H.

PY - 1984

Y1 - 1984

N2 - Recently the left ventricular assist device (LVAD) has been applied to treatment of profound left ventricular failure (LVF) because of its ability to effectively replace cardiac pump function. For clinical use, the authors have developed a new LVAD system consisting of an air-driven, diaphragm-type pump and an automatic control drive unit. In the research reported in this paper, the authors have evaluated the effect of this LVAD system on profound LVF in chronic animal experiments and studied the recovery process of the failing heart from induced profound LVF using left ventriculography (LVG) as well as conventional hemodynamic parameters.

AB - Recently the left ventricular assist device (LVAD) has been applied to treatment of profound left ventricular failure (LVF) because of its ability to effectively replace cardiac pump function. For clinical use, the authors have developed a new LVAD system consisting of an air-driven, diaphragm-type pump and an automatic control drive unit. In the research reported in this paper, the authors have evaluated the effect of this LVAD system on profound LVF in chronic animal experiments and studied the recovery process of the failing heart from induced profound LVF using left ventriculography (LVG) as well as conventional hemodynamic parameters.

UR - http://www.scopus.com/inward/record.url?scp=0021645505&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021645505&partnerID=8YFLogxK

M3 - Conference contribution

C2 - 6533937

AN - SCOPUS:0021645505

VL - 30

SP - 533

EP - 539

BT - Transactions - American Society for Artificial Internal Organs

ER -