Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions

Mika Saito, Moeko Tagawa, Chaichang Chen, Yuka Sakurai, Tomoko Matsubasa, Sachiko Kono, Shinichi Tanabe

研究成果: Conference contribution

抄録

The purpose of this study was to investigate the effects of thermal conditions created by radiant cooling systems on thermal sensation and then to propose comfortable conditions in residential buildings in hot and humid climates. The study includes a subjective experiment and a thermal manikin experiment, which were conducted in model living rooms inside a climate chamber. Both experiments were conducted in 18 different thermal conditions. The results suggest that the influence of constitution cannot be ignored because the psychological response was extremely different from subjects with cold constitution and those without it. Comfortable conditions were determined based on thermal sensation, skin temperature, and sensible heat loss, then it is proposed that the comfortable range of operative temperature considering differences in constitution is 25.7°C to 28.7°C. Moreover, it was suggested that thermal comfort was enhanced by using floor cooling and radiator even under hot environment.

元の言語English
ホスト出版物のタイトルHealthy Buildings Europe 2017
出版者International Society of Indoor Air Quality and Climate
ISBN(印刷物)9788379472604
出版物ステータスPublished - 2017 1 1
外部発表Yes
イベントHealthy Buildings Europe 2017, HB 2017 - Lublin, Poland
継続期間: 2017 7 22017 7 5

Other

OtherHealthy Buildings Europe 2017, HB 2017
Poland
Lublin
期間17/7/217/7/5

Fingerprint

Thermal comfort
Cooling systems
Experiments
Radiators
Heat losses
Skin
Hot Temperature
Cooling
Temperature

ASJC Scopus subject areas

  • Civil and Structural Engineering

これを引用

Saito, M., Tagawa, M., Chen, C., Sakurai, Y., Matsubasa, T., Kono, S., & Tanabe, S. (2017). Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions. : Healthy Buildings Europe 2017 International Society of Indoor Air Quality and Climate.

Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions. / Saito, Mika; Tagawa, Moeko; Chen, Chaichang; Sakurai, Yuka; Matsubasa, Tomoko; Kono, Sachiko; Tanabe, Shinichi.

Healthy Buildings Europe 2017. International Society of Indoor Air Quality and Climate, 2017.

研究成果: Conference contribution

Saito, M, Tagawa, M, Chen, C, Sakurai, Y, Matsubasa, T, Kono, S & Tanabe, S 2017, Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions. : Healthy Buildings Europe 2017. International Society of Indoor Air Quality and Climate, Healthy Buildings Europe 2017, HB 2017, Lublin, Poland, 17/7/2.
Saito M, Tagawa M, Chen C, Sakurai Y, Matsubasa T, Kono S その他. Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions. : Healthy Buildings Europe 2017. International Society of Indoor Air Quality and Climate. 2017
Saito, Mika ; Tagawa, Moeko ; Chen, Chaichang ; Sakurai, Yuka ; Matsubasa, Tomoko ; Kono, Sachiko ; Tanabe, Shinichi. / Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions. Healthy Buildings Europe 2017. International Society of Indoor Air Quality and Climate, 2017.
@inproceedings{5d9e795f8b59445288bb7cd6bf6a1734,
title = "Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions",
abstract = "The purpose of this study was to investigate the effects of thermal conditions created by radiant cooling systems on thermal sensation and then to propose comfortable conditions in residential buildings in hot and humid climates. The study includes a subjective experiment and a thermal manikin experiment, which were conducted in model living rooms inside a climate chamber. Both experiments were conducted in 18 different thermal conditions. The results suggest that the influence of constitution cannot be ignored because the psychological response was extremely different from subjects with cold constitution and those without it. Comfortable conditions were determined based on thermal sensation, skin temperature, and sensible heat loss, then it is proposed that the comfortable range of operative temperature considering differences in constitution is 25.7°C to 28.7°C. Moreover, it was suggested that thermal comfort was enhanced by using floor cooling and radiator even under hot environment.",
keywords = "Cold Constitution, Comfortable Condition, Floor Cooling, Radiator, Subjective Experiment",
author = "Mika Saito and Moeko Tagawa and Chaichang Chen and Yuka Sakurai and Tomoko Matsubasa and Sachiko Kono and Shinichi Tanabe",
year = "2017",
month = "1",
day = "1",
language = "English",
isbn = "9788379472604",
booktitle = "Healthy Buildings Europe 2017",
publisher = "International Society of Indoor Air Quality and Climate",

}

TY - GEN

T1 - Thermal comfort zone of radiant cooling system in residential buildings in hot and humid regions

AU - Saito, Mika

AU - Tagawa, Moeko

AU - Chen, Chaichang

AU - Sakurai, Yuka

AU - Matsubasa, Tomoko

AU - Kono, Sachiko

AU - Tanabe, Shinichi

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The purpose of this study was to investigate the effects of thermal conditions created by radiant cooling systems on thermal sensation and then to propose comfortable conditions in residential buildings in hot and humid climates. The study includes a subjective experiment and a thermal manikin experiment, which were conducted in model living rooms inside a climate chamber. Both experiments were conducted in 18 different thermal conditions. The results suggest that the influence of constitution cannot be ignored because the psychological response was extremely different from subjects with cold constitution and those without it. Comfortable conditions were determined based on thermal sensation, skin temperature, and sensible heat loss, then it is proposed that the comfortable range of operative temperature considering differences in constitution is 25.7°C to 28.7°C. Moreover, it was suggested that thermal comfort was enhanced by using floor cooling and radiator even under hot environment.

AB - The purpose of this study was to investigate the effects of thermal conditions created by radiant cooling systems on thermal sensation and then to propose comfortable conditions in residential buildings in hot and humid climates. The study includes a subjective experiment and a thermal manikin experiment, which were conducted in model living rooms inside a climate chamber. Both experiments were conducted in 18 different thermal conditions. The results suggest that the influence of constitution cannot be ignored because the psychological response was extremely different from subjects with cold constitution and those without it. Comfortable conditions were determined based on thermal sensation, skin temperature, and sensible heat loss, then it is proposed that the comfortable range of operative temperature considering differences in constitution is 25.7°C to 28.7°C. Moreover, it was suggested that thermal comfort was enhanced by using floor cooling and radiator even under hot environment.

KW - Cold Constitution

KW - Comfortable Condition

KW - Floor Cooling

KW - Radiator

KW - Subjective Experiment

UR - http://www.scopus.com/inward/record.url?scp=85053934493&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053934493&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:85053934493

SN - 9788379472604

BT - Healthy Buildings Europe 2017

PB - International Society of Indoor Air Quality and Climate

ER -