Thermal comfort zone of SEMI-outdoor public spaces

Junta Nakano, Shinichi Tanabe

    研究成果: Conference contribution

    抄録

    Adaptive comfort zone and acceptability zone were determined for semi-outdoor public spaces based on seasonal field surveys. Analysis was based on 2284 valid questionnaire responses of actual visitors and corresponding sets of environmental variables measured around each respondent. Thermal preference vote was paired with overall discomfort and unacceptability vote. Occupants tended to feel greater degree of dissatisfaction on warmer SET in HVAC spaces and on cooler SET in non-HVAC spaces. Comfort zone was found to be 18.5 - 30 °C SET in HVAC spaces and 14.5 - 32 °C SET in non-HVAC spaces. Occupants were thermally comfortable in twice the wider range in HVAC spaces and thrice the wider range in non-HVAC spaces than the PPD prediction. Derivation of SET for each occupants accounts for behavioural adaptation, and the difference observed for HVAC spaces and Non-HVAC spaces resulted from the difference in psychological adaptation.

    元の言語English
    ホスト出版物のタイトルIndoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate
    出版者International Society of Indoor Air Quality and Climate
    ページ314-319
    ページ数6
    出版物ステータスPublished - 2014
    イベント13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014 - Hong Kong
    継続期間: 2014 7 72014 7 12

    Other

    Other13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014
    Hong Kong
    期間14/7/714/7/12

    Fingerprint

    Thermal comfort
    Hot Temperature
    Tuberculin
    Psychological Adaptation
    Surveys and Questionnaires
    HVAC

    ASJC Scopus subject areas

    • Pollution
    • Building and Construction
    • Health, Toxicology and Mutagenesis
    • Computer Science Applications

    これを引用

    Nakano, J., & Tanabe, S. (2014). Thermal comfort zone of SEMI-outdoor public spaces. : Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate (pp. 314-319). International Society of Indoor Air Quality and Climate.

    Thermal comfort zone of SEMI-outdoor public spaces. / Nakano, Junta; Tanabe, Shinichi.

    Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate, 2014. p. 314-319.

    研究成果: Conference contribution

    Nakano, J & Tanabe, S 2014, Thermal comfort zone of SEMI-outdoor public spaces. : Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate, pp. 314-319, 13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014, Hong Kong, 14/7/7.
    Nakano J, Tanabe S. Thermal comfort zone of SEMI-outdoor public spaces. : Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate. 2014. p. 314-319
    Nakano, Junta ; Tanabe, Shinichi. / Thermal comfort zone of SEMI-outdoor public spaces. Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate, 2014. pp. 314-319
    @inproceedings{f3da0048920143f1bf06a9dac65d745e,
    title = "Thermal comfort zone of SEMI-outdoor public spaces",
    abstract = "Adaptive comfort zone and acceptability zone were determined for semi-outdoor public spaces based on seasonal field surveys. Analysis was based on 2284 valid questionnaire responses of actual visitors and corresponding sets of environmental variables measured around each respondent. Thermal preference vote was paired with overall discomfort and unacceptability vote. Occupants tended to feel greater degree of dissatisfaction on warmer SET∗ in HVAC spaces and on cooler SET∗ in non-HVAC spaces. Comfort zone was found to be 18.5 - 30 °C SET∗ in HVAC spaces and 14.5 - 32 °C SET∗ in non-HVAC spaces. Occupants were thermally comfortable in twice the wider range in HVAC spaces and thrice the wider range in non-HVAC spaces than the PPD prediction. Derivation of SET∗ for each occupants accounts for behavioural adaptation, and the difference observed for HVAC spaces and Non-HVAC spaces resulted from the difference in psychological adaptation.",
    keywords = "Adaptation, Semi-outdoor environment, Thermal comfort zone",
    author = "Junta Nakano and Shinichi Tanabe",
    year = "2014",
    language = "English",
    pages = "314--319",
    booktitle = "Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate",
    publisher = "International Society of Indoor Air Quality and Climate",

    }

    TY - GEN

    T1 - Thermal comfort zone of SEMI-outdoor public spaces

    AU - Nakano, Junta

    AU - Tanabe, Shinichi

    PY - 2014

    Y1 - 2014

    N2 - Adaptive comfort zone and acceptability zone were determined for semi-outdoor public spaces based on seasonal field surveys. Analysis was based on 2284 valid questionnaire responses of actual visitors and corresponding sets of environmental variables measured around each respondent. Thermal preference vote was paired with overall discomfort and unacceptability vote. Occupants tended to feel greater degree of dissatisfaction on warmer SET∗ in HVAC spaces and on cooler SET∗ in non-HVAC spaces. Comfort zone was found to be 18.5 - 30 °C SET∗ in HVAC spaces and 14.5 - 32 °C SET∗ in non-HVAC spaces. Occupants were thermally comfortable in twice the wider range in HVAC spaces and thrice the wider range in non-HVAC spaces than the PPD prediction. Derivation of SET∗ for each occupants accounts for behavioural adaptation, and the difference observed for HVAC spaces and Non-HVAC spaces resulted from the difference in psychological adaptation.

    AB - Adaptive comfort zone and acceptability zone were determined for semi-outdoor public spaces based on seasonal field surveys. Analysis was based on 2284 valid questionnaire responses of actual visitors and corresponding sets of environmental variables measured around each respondent. Thermal preference vote was paired with overall discomfort and unacceptability vote. Occupants tended to feel greater degree of dissatisfaction on warmer SET∗ in HVAC spaces and on cooler SET∗ in non-HVAC spaces. Comfort zone was found to be 18.5 - 30 °C SET∗ in HVAC spaces and 14.5 - 32 °C SET∗ in non-HVAC spaces. Occupants were thermally comfortable in twice the wider range in HVAC spaces and thrice the wider range in non-HVAC spaces than the PPD prediction. Derivation of SET∗ for each occupants accounts for behavioural adaptation, and the difference observed for HVAC spaces and Non-HVAC spaces resulted from the difference in psychological adaptation.

    KW - Adaptation

    KW - Semi-outdoor environment

    KW - Thermal comfort zone

    UR - http://www.scopus.com/inward/record.url?scp=84924671004&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84924671004&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:84924671004

    SP - 314

    EP - 319

    BT - Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate

    PB - International Society of Indoor Air Quality and Climate

    ER -