THREE DIMENSIONAL PERMEABILITY MEASUREMENTS.

Nobuo Morita, K. E. Gray

    研究成果: Chapter

    1 被引用数 (Scopus)

    抄録

    Procedures are provided to calculate principal permeabilities and directions from data obtained with a whole core type permeameter which has radial and axial flow measurement capabilities with two openings attached to cylindrical curved surface. The conventional plug method to determine anisotropic permeability was also modified to improve its accuracy; plug number and sample spacing were rigorously designed using error sensitivity numbers. To check the validity of the apparatus, experiments were run using anisotropic Berea sandstone.

    本文言語English
    ホスト出版物のタイトルSociety of Petroleum Engineers of AIME, (Paper) SPE
    Place of PublicationDallas, Tex
    出版社Soc of Pet Eng of AIME
    出版ステータスPublished - 1980
    イベントSoc Pet Eng AIME Pap SPE Presented at the Annu Fall Tech Conf and Exhib, 55th - Dallas, TX, USA
    継続期間: 1980 9 211980 9 24

    Other

    OtherSoc Pet Eng AIME Pap SPE Presented at the Annu Fall Tech Conf and Exhib, 55th
    CityDallas, TX, USA
    Period80/9/2180/9/24

    ASJC Scopus subject areas

    • 工学(全般)

    フィンガープリント

    「THREE DIMENSIONAL PERMEABILITY MEASUREMENTS.」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

    引用スタイル