Time series analysis of the effectiveness and safety of capsule endoscopy between the premarketing and postmarketing settings: A meta-analysis

Kazuo Iijima, Mitsuo Umezu, Kiyotaka Iwasaki

研究成果: Article査読

3 被引用数 (Scopus)

抄録

Background Clinical studies for assessing the effectiveness and safety in a premarketing setting are conducted under time and cost constraints. In recent years, postmarketing data analysis has been given more attention. However, to our knowledge, no studies have compared the effectiveness and the safety between the pre- and postmarketing settings. In this study, we aimed to investigate the importance of the postmarketing data analysis using clinical data. Methods and Findings Studies on capsule endoscopy with rich clinical data in both pre- and postmarketing settings were selected for the analysis. For effectiveness, clinical studies published before October 10, 2015 comparing capsule endoscopy and conventional flexible endoscopy measuring the detection ratio of obscure gastrointestinal bleeding were selected (premarketing: 4 studies and postmarketing: 8 studies) from PubMed (MEDLINE), Cochrane Library, EMBASE and Web of Science. Among the 12 studies, 5 were blinded and 7 were non-blinded. A time series meta-analysis was conducted. Effectiveness (odds ratio) decreased in the postmarketing setting (premarketing: 5.19 [95% confidence interval: 3.07-8.76] vs. postmarketing: 1.48 [0.81-2.69]). The change in odds ratio was caused by the increase in the detection ratio with flexible endoscopy as the control group. The efficacy of capsule endoscopy did not change between pre- and postmarketing settings. Heterogeneity (I2 ) increased in the postmarketing setting because of one study. For safety, in terms of endoscope retention in the body, data from the approval summary and adverse event reports were analyzed. The incidence of retention decreased in the postmarketing setting (premarketing: 0.75% vs postmarketing: 0.095%). The introduction of the new patency capsule for checking the patency of the digestive tract might contribute to the decrease. Conclusions Effectiveness and safety could change in the postmarketing setting. Therefore, time series meta-analyses could be useful to continuously monitor the effectiveness of medical device in clinical practices.

本文言語English
論文番号e0153662
ジャーナルPloS one
11
6
DOI
出版ステータスPublished - 2016 6

ASJC Scopus subject areas

  • 生化学、遺伝学、分子生物学(全般)
  • 農業および生物科学(全般)
  • 一般

フィンガープリント

「Time series analysis of the effectiveness and safety of capsule endoscopy between the premarketing and postmarketing settings: A meta-analysis」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル