VAPOUR PRESSURE MEASUREMENT OF GeS, SnS AND CdS BY THE TRANSPIRATION-MASS SPECTROMETER SYSTEM.

Shinichi Nakamura, Akio Fuwa

    研究成果: Article

    3 引用 (Scopus)

    抄録

    The transpiration mass spectrometer system has been upgraded for better sensitivity and detectability by provision of a molecular beam chopping device, a skimmer orifice and a higher evacuation pumping system. Using this improved systems, the vapor species and pressure GeS, SnS and CdS have been measured.

    元の言語English
    ページ(範囲)124-130
    ページ数7
    ジャーナルNippon Kinzoku Gakkai-si
    51
    発行部数2
    出版物ステータスPublished - 1987 2

    Fingerprint

    transpiration
    Transpiration
    Molecular beams
    orifices
    Mass spectrometers
    pressure measurement
    Pressure measurement
    Orifices
    Vapor pressure
    vapor pressure
    molecular beams
    mass spectrometers
    pumping
    Vapors
    vapors
    sensitivity

    ASJC Scopus subject areas

    • Engineering(all)

    これを引用

    VAPOUR PRESSURE MEASUREMENT OF GeS, SnS AND CdS BY THE TRANSPIRATION-MASS SPECTROMETER SYSTEM. / Nakamura, Shinichi; Fuwa, Akio.

    :: Nippon Kinzoku Gakkai-si, 巻 51, 番号 2, 02.1987, p. 124-130.

    研究成果: Article

    Nakamura, Shinichi ; Fuwa, Akio. / VAPOUR PRESSURE MEASUREMENT OF GeS, SnS AND CdS BY THE TRANSPIRATION-MASS SPECTROMETER SYSTEM. :: Nippon Kinzoku Gakkai-si. 1987 ; 巻 51, 番号 2. pp. 124-130.
    @article{e6718b6dfa274522b207a95547aed9d2,
    title = "VAPOUR PRESSURE MEASUREMENT OF GeS, SnS AND CdS BY THE TRANSPIRATION-MASS SPECTROMETER SYSTEM.",
    abstract = "The transpiration mass spectrometer system has been upgraded for better sensitivity and detectability by provision of a molecular beam chopping device, a skimmer orifice and a higher evacuation pumping system. Using this improved systems, the vapor species and pressure GeS, SnS and CdS have been measured.",
    author = "Shinichi Nakamura and Akio Fuwa",
    year = "1987",
    month = "2",
    language = "English",
    volume = "51",
    pages = "124--130",
    journal = "Nippon Kinzoku Gakkaishi/Journal of the Japan Institute of Metals",
    issn = "0021-4876",
    publisher = "Japan Institute of Metals (JIM)",
    number = "2",

    }

    TY - JOUR

    T1 - VAPOUR PRESSURE MEASUREMENT OF GeS, SnS AND CdS BY THE TRANSPIRATION-MASS SPECTROMETER SYSTEM.

    AU - Nakamura, Shinichi

    AU - Fuwa, Akio

    PY - 1987/2

    Y1 - 1987/2

    N2 - The transpiration mass spectrometer system has been upgraded for better sensitivity and detectability by provision of a molecular beam chopping device, a skimmer orifice and a higher evacuation pumping system. Using this improved systems, the vapor species and pressure GeS, SnS and CdS have been measured.

    AB - The transpiration mass spectrometer system has been upgraded for better sensitivity and detectability by provision of a molecular beam chopping device, a skimmer orifice and a higher evacuation pumping system. Using this improved systems, the vapor species and pressure GeS, SnS and CdS have been measured.

    UR - http://www.scopus.com/inward/record.url?scp=0023292576&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0023292576&partnerID=8YFLogxK

    M3 - Article

    AN - SCOPUS:0023292576

    VL - 51

    SP - 124

    EP - 130

    JO - Nippon Kinzoku Gakkaishi/Journal of the Japan Institute of Metals

    JF - Nippon Kinzoku Gakkaishi/Journal of the Japan Institute of Metals

    SN - 0021-4876

    IS - 2

    ER -