抄録
This paper describes the results of experimental investigation on the effects of damper winding of a 4-pole synchronous generator at the synchronous generator transient. It is known in the simulation that the damper winding acts effectively at the synchronous generator transient condition. However, experimental proof has not been performed yet. Then, experiments on damper effects were conducted in this paper using a laboratory-scale power system. The damper winding of tested generator consists of 5 damper bars each pole and the number of working damper bars can be changed manually. Damper currents at each bar were measured by a Rogowski coil. FFT analysis was applied to both damper currents and armature currents under different operating conditions. Relationships between damper currents in the rotor and armature currents in the stator were made clearer than before.
本文言語 | English |
---|---|
ページ(範囲) | 447-454 |
ページ数 | 8 |
ジャーナル | IEEJ Transactions on Power and Energy |
巻 | 131 |
号 | 5 |
DOI | |
出版ステータス | Published - 2011 |
ASJC Scopus subject areas
- エネルギー工学および電力技術
- 電子工学および電気工学