Virus removal from hemoglobin solution using planova membrane

Y. Naito, I. Fukutomi, Y. Masada, H. Sakai, S. Takeoka, E. Tsuchida, H. Abe, J. Hirayama, K. Ikebuchi, H. Ikeda

研究成果: Article査読

14 被引用数 (Scopus)

抄録

Hemoglobin (Hb) vesicles are artificial oxygen carriers that encapsulate concentrated purified Hb with a phospholipid bilayer membrane. They have been confirmed to have sufficient oxygen-transporting ability. Even though strictly inspected outdated red cells are used as a source of Hb, it is necessary to introduce an additional process that inactivates or removes viruses in the process of Hb purification in order to guarantee the utmost safety from infection. In this study, Hb filtration to remove viruses was tested with Planova 35N and 15N (virus removal fitters with a Bemberg microporous membrane). The permeation flux (LMH) and the permeated ratio of Hb solution ([Hb] = 5.6g/dl) through Planova 35N at 13°C were 361/m2/h and almost 100%, respectively. The values for Planova 15N at 13°C were 151/m2/h and 95%, respectively. The permeation flux increased to 181/m2/h when the temperature was raised to 25°C. Under the same conditions, a high efficiency of removal of a bacteriophage, φX174, was confirmed (>7.7log). These results indicate that Planova 15N is effective for the process of virus removal from Hb solution.

本文言語English
ページ(範囲)141-145
ページ数5
ジャーナルJournal of Artificial Organs
5
2
DOI
出版ステータスPublished - 2002 7 17

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Biomaterials
  • Biomedical Engineering
  • Cardiology and Cardiovascular Medicine